INFURIDER
Gas Detector Oxygen Detector, YF-5800H Ultrasonic Oxygen Detector for Oxygen Concentration Pressure and Flow, Handheld Natural Gas Detector for PSA Oxygen Concentrator, Data Hold Gas Meter
Gas Detector Oxygen Detector, YF-5800H Ultrasonic Oxygen Detector for Oxygen Concentration Pressure and Flow, Handheld Natural Gas Detector for PSA Oxygen Concentrator, Data Hold Gas Meter
Couldn't load pickup availability
Brand: INFURIDER
Features:
- 3-in-1 Gas Meter for PSA Systems: Designed as a professional gas detector for PSA oxygen concentrators, this oxygen detector simultaneously measures oxygen concentration, flow rate, and pressure
- Ultrasonic Gas Leak Detector: Oxygen flow detection range: 0 to 10.0 L/min; resolution: 0.1 L/min; accuracy: ±5% F.S (±0.2 L/min) whichever is greater; oxygen concentration detection range: 21% to 95.6% O2; resolution: 0.1%; accuracy: ±1.5%; oxygen pressure detection range: 0-199KPa; accuracy: ±1%FS
- Multi-Function Oxygen Detector: The natural gas detector has clear backlight readings and one-button data hold function–perfect for low-light environments like home gas detector setups. The 2000mAh battery supports 12-hour operation, exceeding most gas detectors for home natural gas devices in endurance.
- Smart Detector: When using the gas detector for home, please drain the water from the oxygen generator humidification bottle, or remove the humidification bottle directly to prevent water from entering the detector and damaging the instrument.
- Package Contents: Oxygen detector, storage bag, instruction manual, silicone tube (280mm long, 10mm outer diameter, 8mm inner diameter), TYPE-C charging cable. If you have any questions about the natural gas leak detector, you can contact us at any time
model number: 5800H Gas Detector
Part Number: indoor-air-quality-meters
Details: The handheld ultrasonic oxygen detector uses the ultrasonic principle for measurement
1. The gas detector can detect oxygen concentration(C), oxygen flow(F), and oxygen pressure(P)
2. Used to detect the output gas of the PSA oxygen generator(Note: When using, please empty the water in the oxygen generator humidifier bottle, or remove the humidifier bottle directly to prevent water from entering the detector and damaging the instrument).
Functional features: (1)backlight function; (2)Automatic shutdown function; (3)Data retention function
Oxygen flow detection range: 0 to 10.0 L/min; resolution: 0.1 L/min; accuracy: ±5% F.S (±0.2 L/min) whichever is greater;
Oxygen concentration detection range: 21% to 95.6% O2; resolution: 0.1%; accuracy: ±1.5%; Oxygen pressure detection range: 0-199KPa; accuracy: ±1%FS
Package Dimensions: 11.1 x 6.4 x 2.6 inches
Share